Section 10. |
|
LIFESAVING |
|
|
|
|
|
|
|
|
|
|
|
|
|
10.1 |
Ref |
Lifesaving Appliances |
Yes |
No |
N/A |
Cat |
Gp |
10.1.3
10.1.3SOLAS III Reg 19.5 MSC.1/Circ.12 06/Rev 1
10.1.4
SOLAS IX ISM 10.0 MSC Cir 1206
10.1.5SOLAS IX ISM 10.1
10.1.6information only
There are records indicating the launching of the lifeboat(s) in compliance with Statutory requirements
Reference: SOLAS III 19.3.3.3 & MSC.1/Circ.1206/Rev.1 SOLAS III reg 19.3.3.4. In the case of a lifeboat arranged for free-fall launching, at least once every three months during an abandon ship drill the crew shall board the lifeboat, properly secure themselves in their seats and commence launch procedures up to but not including the actual release of the lifeboat (i.e., the release hook shall not be released). The lifeboat shall then either be free-fall launched with only the required operating crew on board, or lowered into the water by means of the secondary means of launching with or without the operating crew on board. In both cases the lifeboat shall thereafter be manoeuvred in the water by the operating crew. At intervals of not more than six months, the lifeboat shall either be launched by free-fall with only the operating crew on board, or simulated launching shall be carried out in accordance with the guidelines developed by the Organization.
Refer to Measures to prevent accidents with lifeboats (MSC.1/Circ.1206/Rev.1)
If a full muster, drill or training session is not held at the
|
Coppola |
The lifeboat davits appear in good condition |
|
- Launching appliance |
Massimiliano |
appointed time, an entry shall be made in the log book stating the circumstances and the extent of the muster, drill or training session held.
Inspector should conduct a random sampling of the items shown below, as fitted. If problems are found, additional sampling should be conducted. For questions answered as 'No', the details of the defect must be entered in the observation.
- Lifeboat Release mechanism
- Launchways |
by |
|
|
Purchased |
|
- Wheels and pulleys |
|
- Falls
- Brake
- Recovery motor - Cut out switch
- Span wire - Life lines
- Access ladder
- Bowsing in pennant
- Pennant quick release - Dock (harbour) pins
- Periodic Servicing of Life boatdavits
If No, how many items were not in good order? _______
A dedicated rescue boat is carried
SI
SI
I NS SI
10.1.7
10.1.7SOLAS III Reg 19.3.3.6
10.1.8SOLASIII Reg 14.1
If Yes: |
|
|
The rescue boat is waterborne monthly |
S |
I |
Monthly launching of dedicated rescue boat is to be carried |
|
|
out as far is reasonable and practicable, otherwise at least |
|
|
three monthly. |
|
|
The rescue boat is ready for use in an emergency |
S |
SI |
Copy of Massimiliano Coppola
Gas |
SIR Page 126 |
Rev. CDI 8/19 |
(C) 2019 Chemical Distribution Institute |
Section 10. |
|
LIFESAVING |
|
|
|
|
|
|
|
|
|
|
|
|
|
10.1 |
Ref |
Lifesaving Appliances |
Yes |
No |
N/A |
Cat |
Gp |
10.1.9
10.1.9SOLAS IX ISM 10.1 MSC Cir 1206
10.1.10Information
10.1.11
10.1.12
10.1.13
10.1.13SOLAS III Reg 20.8.1.1
The rescue boat and its equipment (as fitted) appear in good order
Inspector should conduct a random sampling of the items shown below, as fitted. If problems are found, additional sampling should be conducted. For questions answered as 'No', the details of the defect must be entered in the observation.
-Engine/Fuel
-Propeller
-Rudder and tiller
-Oars / paddles
-Waterproof torch
-Painter
-Searchlight
-Thermal protective aids
-Other small equipment
-Weathertight stowage
-Towing arrangement
-Launching and recovery equipment
If No, how many items were not in good order? _______
The rescue boat is certified as a "fast rescue boat" on Form E
If Yes:
Records indicate liferafts (if inflatable) has been serviced within the appropriate interval
Normal servicing schedule is every 12 months. However,
A minimum of 3 personnel have beenCoppolasuitably trained and certified in the operation of a fast rescue boat
some Administrations, uponMassimilianoapplication, may allow up to
seventeen months, which can be verified from the certificates. In this case, provided the vessel is in compliance with the required frequency, the question should be noted as a YES and a comment entered regarding the actual frequency of inspections.
Purchased |
by |
|
S SI
I NS SI
SI
SI
Copy of Massimiliano Coppola
Gas |
SIR Page 127 |
Rev. CDI 8/19 |
(C) 2019 Chemical Distribution Institute |
Section 10. |
|
LIFESAVING |
|
|
|
|
|
|
|
|
|
|
|
|
|
10.1 |
Ref |
Lifesaving Appliances |
Yes |
No |
N/A |
Cat |
Gp |
10.1.14
10.1.14SOLAS IX ISM 10.1
10.1.15Information
10.1.15
10.1.16SOLAS 1,8 12 Form E SEQ
10.1.17SOLAS III Reg 9.2
10.1.18SOLAS III Reg 9.2
10.1.19SOLAS III Reg 9.2.3
10.1.20SOLAS III Reg 11.4
The liferaft(s) and their equipment, as fitted, appear in good condition.
Inspector should conduct a random sampling of the items shown below, as fitted. If problems are found, additional sampling should be conducted. For questions answered as 'No', the details of the defect must be entered in the observation. If the distance between the fixed lifeboats and the bow exceeds 100 metres must have a liferaft fitted forward (suitable for at least 6 persons).
-Container and seal
-Painter
-Launching cradle
-Hydrostatic release unit (Note: Other than the forward liferaft (if fitted), a separate independent hydrostatic release must be provided for each liferaft.)
-Painters appear correctly attached to weak links
-Liferafts are free of obstructions
-Liferafts are fitted with a separate watertight ID container, exterior to the liferaft container
-Embarkation arrangement, including illumination (see Guidance Note below)
-If davit launched and the davit is shared with the rescue boat, the two hook types are clearly identified for their correct use.
must be capable of illuminating the liferaftCoppolastowage position as well as the area of water into which the liferaft should be
If No, how many items were not in good order? _______
Each lifeboat station must be provided with a means of
illumination. Illumination may be either fixed or portable, and
with permanent lighting, it must be powered from an emergency power supply. If located within the cargo area, lighting must be explosion-proof.
launched. Portable lights,Massimilianowhen used, should have brackets to permit their positioning on both sides of the ship. If provided
The lifeboat/liferaft capacity is adequate for the number of persons on-board in compliance with the Safety Equipment
vicinity of the lifeboats
Certificate |
|
by |
|
|
|
|
|
|
|
|
|
|
|
|
|
Lifeboat operating instructions are displayed on or in the |
|
|
|
|
|
||
|
Purchased |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Liferaft operating instructions are displayed on or in the vicinity of the liferafts
Lifeboat and liferaft operating instructions use IMO recommended symbols
Muster and embarkation station emergency lighting is operational
S SI
I
SSI
SI
SI
SI
SI
Copy of Massimiliano Coppola
Gas |
SIR Page 128 |
Rev. CDI 8/19 |
(C) 2019 Chemical Distribution Institute |
Section 10. |
|
LIFESAVING |
|
|
|
|
|
|
|
|
|
|
|
|
|
10.1 |
Ref |
Lifesaving Appliances |
Yes |
No |
N/A |
Cat |
Gp |
10.1.21
10.1.21SOLAS III/31.1.4
MSC.1/Circ.
1243
If required, "remotely located survival craft" are onboard, |
S I |
comply with the requirements, and are in good |
|
condition/operational. |
|
LIferafts, if located at the aft/forward end of the ship and at a |
|
distance of more than 100m from the closest survival craft, |
|
should be regarded as "remotely located survival craft". A |
|
means of illumination must be provided. Illumination may be |
|
either fixed or portable, and must be capable of illuminating |
|
the liferaft stowage position as well as the area of water into |
|
which the liferaft should be launched. Portable lights, when |
|
used, should have brackets to permit their positioning on both |
|
sides of the ship. A minimum of 2 lifejackets and 2 immersion |
|
suits must be provided. An embarkation ladder or other |
|
means of embarkation enabling descent to the water in a |
|
controlled manner must be provided. |
|
10.1.22
10.1.22SOLAS IX ISM 10.1
10.1.23
10.1.23SOLAS IX ISM 10.1
SOLAS III 32.3 MSC/Circ.104 7 & 1114
10.1.24SOLAS III Reg 32.1.1 Reg
7.1.2
10.1.25SOLAS III Reg 7.1.2 & 7.1.3
SOLAS IX ISM 10.1
10.1.26
10.1.26SOLAS IX ISM
10.1.27SOLAS IX ISM
10.1.28SOLAS IX ISM
10.1.29SOLAS IX ISM
10.1.30SOLAS III Reg 18 LSA Code
10.1.31SOLAS IX ISM
10.1.32SOLAS III Reg
6.3LSA Code
3.1
10.1.33SOLAS IX ISM 10.1
Lifejacket requirements appear to be in order
Lifejackets must be complete with a whistle, light and retroreflective tape. The light must also be within its expiry date. Lifejackets must be suitable for every person onboard (including children or personnel in excess of 140 kg, if onboard).
Immersion suits and / or thermal protective aid requirements
appear to be in order |
Coppola |
|
Immersion suits of an appropriate size must be available for every person on-board. Each suit must be tested in accordance with manufacturer's and Flag State requirements. IMO requires the inspection, including air pressure test, at an
marked |
Massimiliano |
interval not to exceed 3-years. Suits of over 10 years of age are to be inspected and tested at an interval not to exceed 2- years. IMO recommends that the air pressure test is conducted at a shore-based facility, but may be completed onboard if suitable equiment is available.
The required number of lifebuoys are carried and correctly
The following lifebuoy fittings appear in good operating condition, including within expiry date if applicable:
Lifebuoys appear in goodby condition and are fitted, as required, with lines, lightsPurchasedor smoke signals
Self-igniting lights
Self-igniting lights in the cargo area must be intrinsically safe. If not, enter a NO and describe in the comments.
Self-activating smoke signals
Bridge wing quick releases
Buoyant lifelines
There are at least four line throwing appliance projectiles and lines on board
All projectiles (and any ignitors) are within their expiry date
There are at least 12 parachute flares stowed on or near the navigating bridge
Parachute flares are within their expiry date
SI
SI
SI
SI
SI 
SI
SI
SI
SSI
SI
SSI
SI
Copy of Massimiliano Coppola
Gas |
SIR Page 129 |
Rev. CDI 8/19 |
(C) 2019 Chemical Distribution Institute |
Section 10. |
|
LIFESAVING |
|
|
|
|
|
|
|
|
|
|
|
|
|
10.1 |
Ref |
Lifesaving Appliances |
Yes |
No |
N/A |
Cat |
Gp |
10.1.34
10.1.34SOLAS II-2 Reg 13.1 Reg 13.1.2 SOLAS III Reg 11.5
10.1.35
10.1.35SOLAS III Reg 20.3
10.1.36SOLAS III Reg 20.7.2
10.1.37
10.1.37IBC 14.3.3 BCH 3.16.9 SOLAS IX ISM 10.1
10.1.38SOLAS 1 Reg 12 (v)
10.1.39MSC.1/ Circ.1447 & 1182
Emergency escape routes and exits, including those to lifesaving appliances, are clearly marked, unobstructed, and adequately illuminated
Escape routes, including those to lifesaving appliances, should be marked by IMO recommended symbols. At least one must be visible from any position in the alleyway. At any time, including storing, obstructed emergency escape routes will result in a NO answer.
A record of inspections and maintenance of each life-saving appliance is available
There should be evidence that a maintenance programme is in place covering all safety equipment and systems. From the programme it should be possible to identify the maintenance schedule of all items, based either on running hours, calendar time or condition monitoring. The programme can be either paper or computer based but must demonstrate a systematic approach to all safety equipment maintenance.
A report of a monthly inspection of the life-saving appliances is recorded in the log-book (SOLAS III 20.6 (weekly)
A stretcher of suitable design is readily available on board and appears in good condition
The stretcher must be of a design which will enable its use in hoisting a person vertically from a space below deck such as a cargo tank, engine room, pump room or bow thruster access trunking.
The actual number of personnel sailing on board is within the |
||
|
|
Coppola |
limits of the Safety Equipment Certificate (Attachment Form E) |
||
There is a suitable ship-specific plan for the recovery of |
||
persons from the water |
Massimiliano |
|
|
by |
|
Purchased |
|
|
|
|
|
SI
SI
SI
SI
SI
SI
Copy of Massimiliano Coppola
Gas |
SIR Page 130 |
Rev. CDI 8/19 |
(C) 2019 Chemical Distribution Institute |