DICOM PS3.3 2020a - Information Object Definitions |
|
Page 211 |
|||||||||
IODs |
XA |
Enh |
RF |
Enh3D XA3D |
Br |
Br |
RT DX |
MG |
IO |
Par |
||
Modules |
|
XA |
|
RF |
|
CF TomoProj IM |
|
|
Map |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Multi-frame Dimension |
|
U |
|
U |
U |
U |
U |
U |
|
|
|
M |
Mask |
C |
U |
C |
U |
|
|
|
|
|
|
|
|
Display Shutter |
U |
|
U |
|
|
|
|
|
U |
U |
U |
|
Device |
U |
U |
U |
U |
U |
U |
U |
U |
U U |
U |
U |
U |
Intervention |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
|
Specimen |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
Patient Orientation |
|
|
|
|
U |
U |
|
M |
|
|
|
|
Image - Equipment Coordinate |
|
|
|
U |
U |
U |
|
|
|
|
|
|
Relationship |
|
|
|
|
|
|
|
|
|
|
|
|
Cardiac Synchronization |
|
|
|
|
|
|
|
|
|
|
|
U |
Respiratory Synchronization |
|
|
|
|
|
|
|
|
|
|
|
U |
Bulk Motion Synchronization |
|
|
|
|
|
|
|
|
|
|
|
U |
X-Ray Image |
M |
|
M |
|
|
|
|
|
|
|
|
|
Enhanced XA/XRF Image |
|
M |
|
M |
|
|
|
|
|
|
|
|
X-Ray Acquisition |
M |
|
M |
|
|
|
|
|
|
|
|
|
XA/XRF Acquisition |
|
C |
|
C |
|
|
|
|
|
|
|
|
X-Ray Collimator |
U |
|
U |
|
|
|
|
|
U |
U |
U |
|
X-Ray Table |
C |
|
U |
|
|
|
|
|
|
|
|
|
XRF Positioner |
|
|
U |
|
|
|
|
|
|
|
|
|
X-Ray Tomography Acquisition |
|
C |
U |
|
|
|
|
U |
U |
U |
|
|
X-Ray Acquisition Dose |
|
|
|
|
|
|
|
|
U |
U |
U |
|
X-Ray Generation |
|
|
|
|
|
|
|
|
U |
U |
U |
|
X-Ray Filtration |
|
U |
|
U |
|
|
|
|
U |
U |
U |
|
X-Ray Grid |
|
U |
|
U |
|
|
|
|
U |
U |
U |
|
XA Positioner |
M |
|
|
|
|
|
|
|
|
|
|
|
X-Ray Image Intensifier |
|
C |
|
C |
|
|
|
|
|
|
|
|
X-Ray Detector |
|
C |
|
C |
|
|
|
|
|
|
|
|
XA/XRF Multi-frame |
|
U |
|
U |
|
|
|
|
|
|
|
|
Presentation |
|
|
|
|
|
|
|
|
|
|
|
|
X-Ray 3D Image |
|
|
|
|
M |
M |
M |
|
|
|
|
|
X-Ray 3D Angiographic Image |
|
|
|
|
U |
|
|
|
|
|
|
|
Contributing Sources |
|
|
|
|
|
|
|
|
|
|
|
|
X-Ray 3D Craniofacial Image |
|
|
|
|
|
U |
|
|
|
|
|
|
Contributing Sources |
|
|
|
|
|
|
|
|
|
|
|
|
Breast Tomosynthesis |
|
|
|
|
|
|
U |
|
|
|
|
|
Contributing Sources |
|
|
|
|
|
|
|
|
|
|
|
|
X-Ray 3D Angiographic |
|
|
|
|
U |
|
|
|
|
|
|
|
Acquisition |
|
|
|
|
|
|
|
|
|
|
|
|
X-Ray 3D Craniofacial |
|
|
|
|
|
U |
|
|
|
|
|
|
Acquisition |
|
|
|
|
|
|
|
|
|
|
|
|
Breast Tomosynthesis |
|
|
|
|
|
|
U |
|
|
|
|
|
Acquisition |
|
|
|
|
|
|
|
|
|
|
|
|
- Standard -
Page 212 |
DICOM PS3.3 2020a - Information Object Definitions |
|
|
|
|
||||||||
IODs |
XA |
Enh |
RF |
Enh3D XA3D |
Br |
Br |
RT DX |
MG |
IO |
Par |
|||
Modules |
|
XA |
|
RF |
|
CF TomoProj IM |
|
|
|
Map |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X-Ray 3D Reconstruction |
|
|
|
|
U |
U |
U |
|
|
|
|
|
|
EnhancedMammographyImage |
|
|
|
|
|
|
M |
|
|
|
|
|
|
Breast View |
|
|
|
|
|
|
M |
M |
|
|
|
|
|
DX Anatomy Imaged |
|
|
|
|
|
|
|
|
|
M |
M |
M |
|
DX Image |
|
|
|
|
|
|
|
|
|
M |
M |
M |
|
DX Detector |
U |
|
U |
|
|
|
|
|
|
M |
M |
M |
|
DX Positioning |
|
|
|
|
|
|
|
|
|
U |
U |
U |
|
Mammo Image |
|
|
|
|
|
|
|
|
|
|
M |
|
|
Intra-Oral Image |
|
|
|
|
|
|
|
|
|
|
|
M |
|
RT Image |
|
|
|
|
|
|
|
|
M |
|
|
|
|
Parametric Map Image |
|
|
|
|
|
|
|
|
|
|
|
|
M |
Approval |
|
|
|
|
|
|
|
|
U |
|
|
|
|
Overlay Plane |
U |
|
U |
|
|
|
|
|
|
C |
C |
C |
|
Multi-frame Overlay |
C |
|
C |
|
|
|
|
|
|
|
|
|
|
Modality LUT |
C* |
|
C* |
|
|
|
|
|
U |
|
|
|
|
VOI LUT |
U |
|
U |
|
|
|
|
|
U |
C |
C |
C |
|
Image Histogram |
|
|
|
|
|
|
|
|
|
U |
U |
U |
|
Common Instance Reference U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
C |
|
Acquisition Context |
|
M |
|
M |
M |
M |
M |
M |
|
M |
M |
M |
M |
SOP Common |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Frame Extraction |
C |
C |
C |
C |
C |
C |
C |
C |
C |
|
|
|
C |
Table A.1-1c. Composite Information Object Modules Overview - More Images
IODs |
VL ENVL MCVL SL VL WS VL PHVid VLVid VLVid VL IVOCT |
Seg |
||||||||
Modules |
|
|
|
|
|
EN |
MC |
PH |
|
|
|
|
|
|
|
|
|
|
|
|
|
Patient |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Clinical Trial Subject |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Study |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Patient Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
Clinical Trial Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Series |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Clinical Trial Series |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
Segmentation Series |
|
|
|
|
|
|
|
|
|
M |
Whole Slide Microscopy Series |
|
|
|
M |
|
|
|
|
|
|
Intravascular OCT Series |
|
|
|
|
|
|
|
|
M |
|
Frame of Reference |
|
|
M |
M |
|
|
|
|
M |
C |
Synchronization |
|
|
|
|
|
|
|
|
M |
|
Cardiac Synchronization |
|
|
|
|
|
|
|
|
C |
|
General Equipment |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Enhanced General Equipment |
|
|
|
M |
|
|
|
|
M |
M |
- Standard -
|
DICOM PS3.3 2020a - Information Object Definitions |
|
Page 213 |
|||||||
IODs |
VL ENVL MCVL SL VL WS VL PHVid VLVid VLVid VL IVOCT |
Seg |
||||||||
Modules |
|
|
|
|
|
EN |
MC |
PH |
|
|
|
|
|
|
|
|
|
|
|
|
|
General Image |
M |
M |
M |
M |
M |
M |
M |
M |
|
M |
Image Pixel |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Supplemental Palette Color |
|
|
|
|
|
|
|
|
C |
|
Lookup Table |
|
|
|
|
|
|
|
|
|
|
Enhanced Contrast/Bolus |
|
|
|
|
|
|
|
|
M |
|
Cine |
|
|
|
|
|
M |
M |
M |
|
|
Multi-frame |
|
|
|
|
|
M |
M |
M |
|
|
Multi-frame Functional Groups |
|
|
|
M |
|
|
|
|
M |
M |
Multi-frame Dimension |
|
|
|
M |
|
|
|
|
M |
M |
Device |
U |
U |
U |
|
U |
U |
U |
U |
U |
|
Specimen |
U |
C |
M |
M |
C |
C |
C |
C |
|
U |
VL Image |
M |
M |
M |
|
M |
M |
M |
M |
|
|
Slide Coordinates |
|
|
M |
|
|
|
|
|
|
|
Whole Slide Microscopy Image |
|
|
|
M |
|
|
|
|
|
|
Optical Path |
|
U |
U |
M |
|
|
|
|
|
|
Multi-Resolution Navigation |
|
|
|
C |
|
|
|
|
|
|
Slide Label |
|
|
|
C |
|
|
|
|
|
|
Intravascular OCT Image |
|
|
|
|
|
|
|
|
M |
|
Intravascular OCT Acquisition |
|
|
|
|
|
|
|
|
M |
|
Parameters |
|
|
|
|
|
|
|
|
|
|
Intravascular OCT Processing |
|
|
|
|
|
|
|
|
C |
|
Parameters |
|
|
|
|
|
|
|
|
|
|
Intravascular Image Acquisition |
|
|
|
|
|
|
|
|
M |
|
Parameters |
|
|
|
|
|
|
|
|
|
|
Segmentation Image |
|
|
|
|
|
|
|
|
|
M |
Overlay Plane |
U |
U |
U |
|
U |
|
|
|
|
|
Common Instance Reference |
U |
U |
U |
M |
U |
U |
U |
U |
M |
C |
Acquisition Context |
M |
M |
M |
M |
M |
M |
M |
M |
M |
|
ICC Profile |
U |
U |
U |
U |
U |
U |
U |
U |
|
|
SOP Common |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Frame Extraction |
|
|
|
C |
|
C |
C |
C |
C |
C |
Table A.1-1d. Composite Information Object Modules Overview - More Images
IODs |
Oph 8 Oph 16WF OphWF Oph OPT |
OCT |
OCT OPM |
CM |
|||||
Modules |
Bit |
Bit |
St |
3DC |
|
ENF |
BSV |
|
|
|
|
|
|
|
|
|
|
|
|
Patient |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Clinical Trial Subject |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Study |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Patient Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
Clinical Trial Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Series |
M |
M |
M |
M |
M |
M |
M |
M |
M |
- Standard -
Page 214 |
DICOM PS3.3 2020a - Information Object Definitions |
|
|
|
|
|||||
IODs |
|
Oph 8 Oph 16WF OphWF Oph OPT |
OCT |
OCT OPM |
CM |
|||||
Modules |
|
Bit |
Bit |
St |
3DC |
|
ENF |
BSV |
|
|
|
|
|
|
|
|
|
|
|
|
|
Clinical Trial Series |
|
U |
U |
U |
U |
U |
U |
U |
U |
U |
Ophthalmic Tomography Series |
|
|
|
|
|
M |
|
|
|
|
Ophthalmic Tomography En Face Series |
|
|
|
|
|
M |
|
|
|
|
Ophthalmic Tomography B-scan Volume |
|
|
|
|
|
|
M |
|
|
|
Analysis Series |
|
|
|
|
|
|
|
|
|
|
Ophthalmic Thickness Map Series |
|
|
|
|
|
|
|
|
M |
|
Corneal Topography Map Series |
|
|
|
|
|
|
|
|
|
M |
Frame of Reference |
|
|
|
M |
M |
C |
M |
M |
|
M |
Synchronization |
|
M |
M |
M |
M |
C |
|
|
|
|
Cardiac Synchronization |
|
|
|
|
|
C |
|
|
|
|
General Equipment |
|
M |
M |
M |
M |
M |
M |
M |
M |
M |
Enhanced General Equipment |
|
|
|
M |
M |
M |
M |
M |
M |
M |
General Image |
|
M |
M |
M |
M |
|
M |
|
M |
M |
Image Pixel |
|
M |
M |
M |
M |
M |
M |
M |
M |
M |
Palette Color Lookup Table |
|
|
|
|
|
|
C |
|
|
M |
Supplemental Palette Color Lookup Table |
|
|
|
|
|
|
C |
|
||
Enhanced Contrast/Bolus |
|
C |
C |
C |
C |
C |
|
|
|
|
Cine |
|
C |
C |
C |
C |
|
|
|
|
|
Multi-frame |
|
M |
M |
M |
M |
|
|
|
|
|
Multi-frame Functional Groups |
|
|
|
|
|
M |
|
M |
|
|
Multi-frame Dimension |
|
|
|
|
|
M |
|
M |
|
|
Bitmap Display Shutter |
|
|
|
|
|
|
|
|
C |
|
Device |
|
U |
U |
|
|
|
|
|
|
|
Ophthalmic Photography Image |
|
M |
M |
M |
M |
|
|
|
|
|
Wide Field Ophthalmic Photography |
|
|
|
M |
|
|
|
|
|
|
Stereographic Projection |
|
|
|
|
|
|
|
|
|
|
Wide Field Ophthalmic Photography 3D |
|
|
|
M |
|
|
|
|
|
|
Coordinates |
|
|
|
|
|
|
|
|
|
|
WideFieldOphthalmicPhotographyQuality |
|
C |
C |
|
|
|
|
|
||
Rating |
|
|
|
|
|
|
|
|
|
|
Ocular Region Imaged |
|
M |
M |
M |
M |
M |
M |
|
|
|
Ophthalmic Photography Acquisition |
|
M |
M |
M |
M |
|
|
|
M |
M |
Parameters |
|
|
|
|
|
|
|
|
|
|
Ophthalmic Photographic Parameters |
M |
M |
M |
M |
|
|
|
|
|
|
Ophthalmic Tomography Image |
|
|
|
|
|
M |
|
|
|
|
Ophthalmic Tomography Parameters |
|
|
|
|
M |
|
|
|
|
|
Ophthalmic Tomography Acquisition |
|
|
|
|
|
M |
|
|
|
|
Parameters |
|
|
|
|
|
|
|
|
|
|
Ophthalmic Thickness Map |
|
|
|
|
|
|
|
|
M |
|
Ophthalmic Thickness Map Quality Rating |
|
|
|
|
|
|
C |
|
||
Corneal Topography Map Image |
|
|
|
|
|
|
|
|
|
M |
Corneal Topography Map Analysis |
|
|
|
|
|
|
|
|
|
M |
- Standard -
|
DICOM PS3.3 2020a - Information Object Definitions |
|
|
Page 215 |
|||||
IODs |
Oph 8 Oph 16WF OphWF Oph OPT |
OCT |
OCT OPM |
CM |
|||||
Modules |
Bit Bit |
St |
3DC |
ENF |
BSV |
|
|
||
|
|
|
|
|
|
|
|
|
|
OphthalmicOpticalCoherenceTomography |
|
|
|
|
M |
|
|
|
|
En Face Image |
|
|
|
|
|
|
|
|
|
OphthalmicOpticalCoherenceTomography |
|
|
|
|
|
M |
|
|
|
B-scan Volume Analysis Image |
|
|
|
|
|
|
|
|
|
OphthalmicOpticalCoherenceTomography |
|
|
|
|
C |
|
|
|
|
En Face Image Quality Rating |
|
|
|
|
|
|
|
|
|
Common Instance Reference |
U |
U |
U |
U |
U |
U |
U |
U |
|
Acquisition Context |
U |
U |
U |
U |
M |
|
|
M |
M |
ICC Profile |
U |
U |
C |
C |
|
U |
|
|
U |
SOP Common |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Frame Extraction |
C |
C |
C |
C |
C |
|
C |
|
|
Table A.1-2. Composite Information Object Modules Overview - Non-Images |
|
||||||||
IODs |
|
MR |
Raw Data Surface ScanSurface Scan Content |
||||||
Modules |
|
Spectroscopy |
|
Point Cloud Mesh |
Assessment |
||||
|
|
|
|
|
|
|
Result |
||
Patient |
|
M |
M |
|
M |
M |
|
M |
|
Clinical Trial Subject |
|
U |
U |
|
U |
U |
|
U |
|
General Study |
|
M |
M |
|
M |
M |
|
M |
|
Patient Study |
|
U |
U |
|
U |
U |
|
U |
|
Clinical Trial Study |
|
U |
U |
|
U |
U |
|
U |
|
General Series |
|
M |
M |
|
M |
M |
|
M |
|
Clinical Trial Series |
|
U |
U |
|
U |
U |
|
U |
|
Optical Surface Scanner Series |
|
|
|
|
M |
M |
|
|
|
Frame of Reference |
|
M |
U |
|
|
|
|
|
|
Sync. |
|
C |
C |
|
|
|
|
|
|
Cardiac Sync. |
|
C |
|
|
|
|
|
|
|
Respiratory Sync. |
|
C |
|
|
|
|
|
|
|
Bulk Motion Sync. |
|
C |
|
|
|
|
|
|
|
General Equip. |
|
M |
M |
|
M |
M |
|
M |
|
Enhanced General Equip. |
|
M |
|
|
M |
M |
|
M |
|
Multi-frame Functional Groups |
|
M |
|
|
|
|
|
|
|
Multi-frame Dim. |
|
M |
|
|
|
|
|
|
|
Specimen |
|
U |
U |
|
U |
U |
|
|
|
Raw Data |
|
|
M |
|
|
|
|
|
|
MR Spect. |
|
M |
|
|
|
|
|
|
|
MR Spect. Pulse Sequence |
|
C |
|
|
|
|
|
|
|
MR Spect. Data |
|
M |
|
|
|
|
|
|
|
Point Cloud |
|
|
|
|
M |
|
|
|
|
Surface Mesh |
|
|
|
|
|
M |
|
|
|
UV Mapping |
|
|
|
|
U |
U |
|
|
|
Scan Procedure |
|
|
|
|
M |
M |
|
|
|
- Standard -