Page 216 |
DICOM PS3.3 2020a - Information Object Definitions |
|
|
||
IODs |
MR |
Raw Data Surface ScanSurface Scan Content |
|||
Modules |
Spectroscopy |
|
Point Cloud |
Mesh |
Assessment |
|
|
|
|
Result |
|
Content Assessment Results |
|
|
|
|
M |
Acquisition Context |
M |
M |
|
|
|
Common Instance Reference |
|
|
|
|
M |
SOP Common |
M |
M |
M |
M |
M |
Frame Extraction |
C |
|
|
|
|
Table A.1-3. Composite Information Object Modules Overview - More Non-Images
IODs |
LnAutKerSubVisOp IOOPVRegDefFidRWVStrHPSfcColBs Trc |
||||||
Modules |
MxRefMxRefAcyAx Ln |
Reg |
Rl |
SegPalStRes |
|||
Mx |
MxMxMx Cl |
|
|
|
Dsp |
||
Patient |
M M M M M M M M M M M M |
M |
M |
M |
M |
||
Clinical Trial Subject |
U U U U U U U U U U U U |
U |
U |
U |
U |
||
General Study |
M M M M M M M M M M M M |
M |
M |
M |
M |
||
Patient Study |
U U U U U U U U U U U U |
U |
U |
U |
U |
||
Clinical Trial Study |
U U U U U U U U U U U U |
U |
U |
U |
U |
||
General Series |
M M M M M M M M M M M |
M |
M |
M |
M |
||
Clinical Trial Series |
U U U U U U U U |
U |
U |
U |
U |
U |
|
Presentation Series |
|
|
|
|
|
M |
|
Spatial Registration Series |
|
|
M M |
|
|
|
|
Spatial Fiducials Series |
|
|
M |
|
|
|
|
Real World Value Mapping |
|
|
M |
|
|
|
|
Series |
|
|
|
|
|
|
|
Stereometric Series |
|
|
|
M |
|
|
|
Segmentation Series |
|
|
|
|
M |
|
|
Lensometry Msrmnts. Series M |
|
|
|
|
|
|
|
AutorefractionMsrmnts.Series M |
|
|
|
|
|
|
|
Keratometry Msrmnts. Series |
M |
|
|
|
|
|
|
SubjectiveRefractionMsrmnts. |
M |
|
|
|
|
|
|
Series |
|
|
|
|
|
|
|
Visual Acuity Msrmnts. Series |
M |
|
|
|
|
|
|
Ophthalmic Axial Msrmnts. |
|
M |
|
|
|
|
|
Series |
|
|
|
|
|
|
|
Intraocular Lens Calculations |
|
M |
|
|
|
|
|
Series |
|
|
|
|
|
|
|
Visual Field Static Perimetry |
|
M |
|
|
|
|
|
Msrmnts. Series |
|
|
|
|
|
|
|
Tractography Results Series |
|
|
|
|
|
|
M |
Frame of Reference |
|
|
M M |
|
M |
|
M |
General Equipment |
M M M M M M M M M M M M |
M |
M |
M |
M |
||
Enhanced General EquipmentM M M M M M M M |
M |
|
M |
M |
M |
||
Specimen |
|
|
|
|
|
|
U |
Palette Color LUT |
|
|
|
|
|
M |
|
- Standard -
|
|
DICOM PS3.3 2020a - Information Object Definitions |
|
|
Page 217 |
|
IODs |
LnAutKerSubVisOp IOOPVRegDefFidRWVStrHPSfcColBs Trc |
|||||
Modules |
MxRefMxRefAcyAx Ln |
Reg |
Rl |
SegPalStRes |
||
|
Mx MxMxMx Cl |
|
|
|
Dsp |
|
Stereometric Relationship |
|
|
|
M |
|
|
ICC Profile |
|
|
|
|
|
M |
Spatial Registration |
|
|
M |
|
|
|
DeformableSpatialRegistration |
|
M |
|
|
|
|
Spatial Fiducials |
|
|
M |
|
|
|
Real World Value Mapping |
|
|
M |
|
|
|
Surface Segmentation |
|
|
|
|
M |
|
Surface Mesh |
|
|
|
|
M |
|
Color Palette Definition |
|
|
|
|
|
M |
Structured Display |
|
|
|
|
|
M |
Structured Display Image Box |
|
|
|
|
M |
|
Structured Display Annotation |
|
|
|
|
U |
|
General Ophthalmic RefractiveM M M M M M M |
|
|
|
|
||
Msrmnts. |
|
|
|
|
|
|
Lensometry Msrmnts. |
M |
|
|
|
|
|
Autorefraction Msrmnts. |
|
M |
|
|
|
|
Keratometry Msrmnts. |
|
M |
|
|
|
|
SubjectiveRefractionMsrmnts. |
M |
|
|
|
|
|
Visual Acuity Msrmnts. |
|
M |
|
|
|
|
Ophthalmic Axial Msrmnts. |
|
M |
|
|
|
|
Intraocular Lens Calculations |
|
M |
|
|
|
|
Visual Field Static Perimetry |
|
M |
|
|
|
|
Test Parameters |
|
|
|
|
|
|
Visual Field Static Perimetry |
|
M |
|
|
|
|
Test Reliability |
|
|
|
|
|
|
Visual Field Static Perimetry |
|
M |
|
|
|
|
Test Msrmnts. |
|
|
|
|
|
|
Visual Field Static Perimetry |
|
M |
|
|
|
|
Test Results |
|
|
|
|
|
|
Ophthalmic Patient Clinical |
|
U |
|
|
|
|
Information and Test Lens |
|
|
|
|
|
|
Parameters |
|
|
|
|
|
|
Common Instance Reference |
|
|
M M M M |
M |
C |
M M |
Hanging Protocol Definition |
|
|
|
M |
|
|
Hanging Protocol Environment |
|
|
M |
|
|
|
Hanging Protocol Display |
|
|
|
M |
|
|
Tractography Results |
|
|
|
|
|
M |
SOP Common |
M M M M M M M M M M M M |
M MM M M M |
||||
- Standard -
Page 218 DICOM PS3.3 2020a - Information Object Definitions
Table A.1-4. Composite Information Object Modules Overview - Radiotherapy
IODs |
RT Dose RT RTPlan RT |
RT |
RT RT Ion RT Ion RT |
RT |
||||||
Modules |
|
Struc |
BeamBrachySum Plan BeamsBeamsBrachy |
|||||||
|
Set |
|
Rec |
Rec |
|
|
Treat Delivery App |
|||
|
|
|
|
|
|
|
|
Rec |
Inst |
Setup |
|
|
|
|
|
|
|
|
|
|
Delivery |
|
|
|
|
|
|
|
|
|
|
Inst |
Patient |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Clinical Trial Subject |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Study |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Patient Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
Clinical Trial Study |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
General Series |
|
|
|
|
|
|
|
|
M |
M |
Clinical Trial Series |
U |
U |
U |
U |
U |
U |
U |
U |
U |
U |
RT Series |
M |
M |
M |
M |
M |
M |
M |
M |
|
|
Frame of Reference |
M |
U |
U |
|
|
|
M |
|
|
|
General Equipment |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Enhanced General Equipment |
|
|
|
|
|
|
|
|
|
M |
General Image |
C |
|
|
|
|
|
|
|
|
|
Image Plane |
C |
|
|
|
|
|
|
|
|
|
Image Pixel |
C |
|
|
|
|
|
|
|
|
|
Multi-frame |
C |
|
|
|
|
|
|
|
|
|
RT Dose |
M |
|
|
|
|
|
|
|
|
|
RT DVH |
U |
|
|
|
|
|
|
|
|
|
Structure Set |
C |
M |
|
|
|
|
|
|
|
|
ROI Contour |
C |
M |
|
|
|
|
|
|
|
|
RT Dose ROI |
C |
|
|
|
|
|
|
|
|
|
RT ROI Observations |
|
M |
|
|
|
|
|
|
|
|
RT General Treatment Record |
|
|
|
M |
M |
M |
|
M |
|
|
RT Treatment Machine Record |
|
|
|
M |
M |
|
|
M |
|
|
Measured Dose Reference Record |
|
|
U |
U |
|
|
U |
|
|
|
Calculated Dose Reference Record |
|
|
U |
U |
|
|
U |
|
|
|
RT Beams Session Record |
|
|
|
M |
|
|
|
|
|
|
RT Ion Beams Session Record |
|
|
|
|
|
|
|
M |
|
|
RT Brachy Session Record |
|
|
|
|
M |
|
|
|
|
|
RT Treatment Summary Record |
|
|
|
U |
U |
M |
|
U |
|
|
RT General Plan |
|
|
M |
|
|
|
M |
|
|
|
RT Prescription |
|
|
U |
|
|
|
U |
|
|
|
RT Tolerance Tables |
|
|
U |
|
|
|
|
|
|
|
RT Ion Tolerance Tables |
|
|
|
|
|
|
U |
|
|
|
RT Patient Setup |
|
|
U |
U |
U |
|
U |
U |
|
|
RT Fraction Scheme |
|
|
U |
|
|
|
U |
|
|
|
RT Beams |
|
|
C |
|
|
|
|
|
|
|
RT Ion Beams |
|
|
|
|
|
|
M |
|
|
|
- Standard -
|
DICOM PS3.3 2020a - Information Object Definitions |
|
|
Page 219 |
||||||
IODs |
RT Dose RT RTPlan RT |
RT |
RT RT Ion RT Ion RT |
RT |
||||||
Modules |
|
Struc |
BeamBrachySum Plan BeamsBeamsBrachy |
|||||||
|
Set |
|
Rec Rec |
|
|
Treat Delivery App |
||||
|
|
|
|
|
|
|
|
Rec |
Inst |
Setup |
|
|
|
|
|
|
|
|
|
|
Delivery |
|
|
|
|
|
|
|
|
|
|
Inst |
RT Brachy Application Setups |
|
|
C |
|
|
|
|
|
|
|
RT Beams Delivery Instruction |
|
|
|
|
|
|
|
|
M |
|
RT Brachy Application Setup |
|
|
|
|
|
|
|
|
|
M |
Delivery Instruction |
|
|
|
|
|
|
|
|
|
|
Approval |
|
U |
U |
|
|
|
U |
|
|
|
Overlay Plane |
U |
|
|
|
|
|
|
|
|
|
Multi-frame Overlay |
U |
|
|
|
|
|
|
|
|
|
Modality LUT |
U |
|
|
|
|
|
|
|
|
|
Common Instance Reference |
U |
U |
U |
U |
U |
U |
U |
U |
C |
M |
SOP Common |
M |
M |
M |
M |
M |
M |
M |
M |
M |
M |
Frame Extraction |
C |
|
|
|
|
|
|
|
|
|
Table A.1-4b. Composite Information Object Modules Overview - Second Generation Radiotherapy |
||||||||||
IODs |
|
RT Physn |
RT Seg RT Rad SetC-Arm P-E Tomo Rad Rob Arm |
|||||||
Modules |
|
Intent |
Annot |
|
|
Rad |
|
|
Rad |
|
|
|
|
|
|
|
|
|
|
|
|
Patient |
|
M |
|
M |
M |
M |
|
M |
M |
|
Clinical Trial Subject |
|
U |
|
U |
U |
U |
|
U |
U |
|
General Study |
|
M |
|
M |
M |
M |
|
M |
M |
|
Patient Study |
|
U |
|
U |
U |
U |
|
U |
U |
|
Clinical Trial Study |
|
U |
|
U |
U |
U |
|
U |
U |
|
General Series |
|
|
|
|
M |
M |
|
M |
M |
|
Clinical Trial Series |
|
U |
|
U |
U |
U |
|
U |
U |
|
Enhanced RT Series |
|
M |
|
M |
M |
M |
|
M |
M |
|
General Equipment |
|
M |
|
M |
M |
M |
|
M |
M |
|
Enhanced General Equipment |
|
M |
|
M |
M |
M |
|
M |
M |
|
Frame of Reference |
|
|
|
|
M |
M |
|
M |
M |
|
Radiotherapy Common Instance |
|
M |
|
M |
M |
M |
|
M |
M |
|
RT Physician Intent |
|
M |
|
|
|
|
|
|
|
|
RT Prescription |
|
U |
|
|
|
|
|
|
|
|
RT Treatment Phase Intent |
|
C |
|
|
|
|
|
|
|
|
RT Segment Annotation |
|
|
|
M |
|
|
|
|
|
|
RT Radiation Set |
|
|
|
|
M |
|
|
|
|
|
RT Dose Contribution |
|
|
|
|
C |
|
|
|
|
|
RT Delivery Device Common |
|
|
|
|
|
M |
|
M |
M |
|
RT Radiation Common |
|
|
|
|
|
M |
|
M |
M |
|
C-Arm Photon-Electron Delivery Device |
|
|
|
|
M |
|
|
|
|
|
C-Arm Photon-Electron Beam |
|
|
|
|
|
M |
|
|
|
|
Tomotherapeutic Delivery Device |
|
|
|
|
|
|
|
M |
|
|
- Standard -
Page 220 |
DICOM PS3.3 2020a - Information Object Definitions |
|
|
|||
IODs |
RT Physn |
RT Seg RT Rad SetC-Arm P-E Tomo Rad |
Rob Arm |
|||
Modules |
Intent |
Annot |
|
Rad |
|
Rad |
|
|
|
|
|
|
|
Tomotherapeutic Beam |
|
|
|
|
M |
|
Robotic-Arm Delivery Device |
|
|
|
|
|
M |
Robotic-Arm Path |
|
|
|
|
|
M |
Segment Reference |
|
M |
|
|
|
|
General Reference |
M |
M |
M |
M |
M |
M |
Common Instance Reference |
M |
M |
M |
M |
M |
M |
SOP Common |
M |
M |
M |
M |
M |
M |
Table A.1-5. Composite Information Object Modules Overview - Implants
IODs |
Generic Implant |
Implant AssemblyImplant Template |
|
Modules |
Template |
Template |
Group |
|
|
|
|
Generic Implant Template Description |
M |
|
|
Generic Implant Template 2D Drawings |
C |
|
|
Generic Implant Template 3D Models |
C |
|
|
Generic Implant Template Mating Features |
U |
|
|
Generic Implant Template Planning Landmarks |
U |
|
|
Implant Assembly Template |
|
M |
|
Implant Template Group |
|
|
M |
SOP Common |
M |
M |
M |
Surface Mesh |
U |
|
|
Table A.1-6. Composite Information Object Modules Overview - Presentation States
IODs |
Gray PresCol Pres Pseudo |
Blend |
XA RF |
Planar Vol Rend |
Adv |
||||
Modules |
State |
State |
Col Pres Pres |
PresStateMPR Vol Vol Pres |
Blend |
||||
|
|
State |
State |
|
PresState State |
|
Pres |
||
|
|
|
|
|
|
|
|
|
State |
Patient |
M |
M |
M |
M |
M |
M |
M |
M |
|
Clinical Trial Subject |
U |
U |
U |
U |
U |
U |
U |
U |
|
General Study |
M |
M |
M |
M |
M |
M |
M |
M |
|
Patient Study |
U |
U |
U |
U |
U |
U |
U |
U |
|
Clinical Trial Study |
U |
U |
U |
U |
U |
U |
U |
U |
|
General Series |
M |
M |
M |
M |
M |
M |
M |
M |
|
Clinical Trial Series |
U |
U |
U |
U |
U |
U |
U |
U |
|
Presn. Series |
M |
M |
M |
M |
M |
M |
M |
M |
|
Frame of Reference |
|
|
|
|
|
M |
M |
M |
|
General Equip. |
M |
M |
M |
M |
M |
M |
M |
M |
|
Enhanced General Equip. |
|
|
|
|
M |
M |
M |
M |
|
Mask |
C |
|
C |
|
|
|
|
|
|
Display Shutter |
C |
C |
C |
|
|
|
|
|
|
Bitmap Display Shutter |
C |
C |
C |
|
C |
|
|
|
|
Palette Color LUT |
|
|
M |
M |
|
|
|
|
|
- Standard -