Материал: part03

Внимание! Если размещение файла нарушает Ваши авторские права, то обязательно сообщите нам

DICOM PS3.3 2020a - Information Object Definitions​

Page 1531​

Attribute Name​

Tag​

Attribute Description​

 

>>Human Performer's Organization​

(0040,4036)​

Organization to which the human performer is accountable for​

 

 

the activities in the Procedure Step.​

 

>Performed Station Name Code​

(0040,4028)​

Names within the enterprise of the equipment that performed​

Sequence​

 

the Procedure Step. This name may be the same as the AE​

 

 

Title, but does not have to be.​

 

 

 

Zero or more Items shall be included in this Sequence.​

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

 

>Performed Station Class Code​

(0040,4029)​

Classes of the equipment that created the Procedure Step.​

Sequence​

 

Zero or more Items shall be included in this Sequence.​

 

 

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

 

>Performed Station Geographic​

(0040,4030)​

Geographic locations of the equipment that created Procedure​

Location Code Sequence​

 

Step.​

 

 

 

Zero or more Items shall be included in this Sequence.​

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

 

>Performed Procedure Step Start​

(0040,4050)​

Date and Time at which the Procedure Step started.​

DateTime​

 

 

 

>PerformedProcedureStepDescription​

(0040,0254)​

Institution-generated description or classification of the​

 

 

Procedure Step that was performed.​

 

>Comments on the Performed​

(0040,0280)​

User-defined comments on the Performed Procedure Step.​

Procedure Step​

 

 

 

>Performed Workitem Code Sequence​

(0040,4019)​

A Sequence that conveys the type of procedure performed.​

 

 

Zero or more Items shall be present in this Sequence.​

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

Baseline CID is CID 9231 “Workitem Definition”.​

 

 

 

Note​

 

 

 

This CID has generic workitems. An implementation​

 

 

may choose to define more specific, detailed​

 

 

 

workitems.​

 

>Performed Processing Parameters​

(0074,1212)​

Parameters used to perform the procedure.​

 

Sequence​

 

Zero or more Items shall be present in this Sequence​

 

 

>>Include Table 10-2 “Content Item Macro Attributes Description”​No Baseline CIDs are defined for Concept Name Code​ Sequence or Concept Code Sequence.​

>>Content Item Modifier Sequence​

(0040,0441)​

Sequence that specifies modifiers for a Performed Processing​

 

 

Parameter Content Item.​

One or more Items are permitted in this Sequence.​

>>>Include Table 10-2 “Content Item Macro Attributes Description”​No Baseline CIDs are defined for Concept Name Code​ Sequence or Concept Code Sequence.​

>Performed Procedure Step End​

(0040,4051)​

Date and Time at which the Procedure Step ended.​

DateTime​

 

 

>Output Information Sequence​

(0040,4033)​

ReferencestoinformationcreatedaspartoftheProcedureStep.​

 

 

ReferencingunencapsulatedHL7documentsisdescribedfurther​

 

 

in Section C.12.1.1.6.​

Zero or more Items shall be included in this Sequence.​

- Standard -​

Page 1532​

DICOM PS3.3 2020a - Information Object Definitions​

Attribute Name​

Tag​

Attribute Description​

>>Include Table 10-3b “Referenced Instances and Access Macro​ Attributes”​

C.30.4 Unified Procedure Step Relationship Module​

Table C.30.4-1 specifies the Attributes that describe the relationship of a Unified Procedure Step (UPS).​

Table C.30.4-1. Unified Procedure Step Relationship Module Attributes​

Attribute Name​

Tag​

Attribute Description​

Patient's Name​

(0010,0010)​

Patient's full legal name.​

Patient ID​

(0010,0020)​

Primary identifier for the patient.​

 

 

Note​

 

 

In the case of imaging a group of small animals​

 

 

simultaneously, the single value of this identifier​

 

 

corresponds to the identification of the entire group. See​

 

 

also Section C.7.1.4.1.1.​

 

 

See Section C.30.4.1​

Include Table 10-18 “Issuer of Patient ID Macro Attributes”​

 

Type of Patient ID​

(0010,0022)​

The type of identifier in the Patient ID (0010,0020).​

 

 

Defined Terms:​

 

 

TEXT​

 

 

RFID​

 

 

BARCODE​

 

 

Note​

 

 

1.​The identifier is coded as a string regardless of the​

 

 

type, not as a binary value.​

 

 

2.​When this Attribute has a value of BARCODE,​

 

 

Patient ID (0010,0020) may or may not have the​

 

 

same value as Barcode Value (2200,0005) in the​

 

 

SOP Common Module, if present.​

Other Patient IDs Sequence​

(0010,1002)​

Identificationnumbersorcodesusedtoidentifythepatient,which​

 

 

may or may not be human readable, and may or may not have​

 

 

been obtained from an implanted or attached device such as an​

 

 

RFID or barcode.​

 

 

Zero or more Items shall be included in this Sequence.​

>Patient ID​

(0010,0020)​

An identifier for the patient.​

>Include Table 10-18 “Issuer of Patient ID Macro Attributes”​

 

- Standard -​

 

DICOM PS3.3 2020a - Information Object Definitions​

Page 1533​

Attribute Name​

Tag​

Attribute Description​

 

>Type of Patient ID​

(0010,0022)​

The type of identifier in the Patient ID (0010,0020) in this Item.​

 

 

Defined Terms:​

 

 

 

TEXT​

 

 

 

RFID​

 

 

 

BARCODE​

 

 

 

Note​

 

 

 

1.​The identifier is coded as a string regardless of the​

 

 

type, not as a binary value.​

 

 

 

2.​When this Attribute has a value of BARCODE,​

 

 

Patient ID (0010,0020) may or may not have the​

 

 

same value as Barcode Value (2200,0005) in the​

 

 

SOP Common Module, if present.​

 

Patient's Birth Date in Alternative​

(0010,0033)​

Date of birth of the named patient in the Alternative Calendar​

Calendar​

 

(0010,0035).​

 

 

 

Note​

 

 

 

No format is specified for alternative calendar dates so​

 

 

none should be assumed.​

 

Patient's Death Date in Alternative​

(0010,0034)​

Date of death of the named patient in the Alternative Calendar​

Calendar​

 

(0010,0035).​

 

 

 

Note​

 

 

 

No format is specified for alternative calendar dates so​

 

 

none should be assumed.​

 

Patient's Alternative Calendar​

(0010,0035)​

TheAlternativeCalendarusedforPatient'sBirthDateinAlternative​

 

 

Calendar (0010,0033) and Patient's Death Date in Alternative​

 

 

Calendar (0010,0034).​

 

 

 

See Section C.7.1.5 for Defined Terms.​

 

 

 

Required if either Patient's Birth Date in Alternative Calendar​

 

 

(0010,0033) or Patient's Alternative Death Date in Calendar​

 

 

(0010,0034) is present.​

 

Patient's Birth Date​

(0010,0030)​

Date of birth of the named patient.​

 

Patient's Sex​

(0010,0040)​

Sex of the named Patient.​

 

Enumerated Values:​

M​male​

F​female​

O​other​

Referenced Patient Photo Sequence​

(0010,1100)​

A photo to confirm the identity of a patient.​

Only a single Item is permitted in this Sequence.​

See C.2.2.1.1.​

>Include Table 10-3b “Referenced Instances and Access Macro​

Attributes”​

- Standard -​

Page 1534​

DICOM PS3.3 2020a - Information Object Definitions​

Attribute Name​

 

Tag​

Attribute Description​

Admission ID​

 

(0038,0010)​

Identification number of the Visit as assigned by the healthcare​

 

 

 

provider​

 

 

 

Note​

 

 

 

Visit and Admission are used interchangeably here. In​

 

 

 

the broader sense, an admission is a type of visit at an​

 

 

 

institution where there is an admission process for​

 

 

 

patients.​

Issuer of Admission ID Sequence​

 

(0038,0014)​

Identifier of the Assigning Authority that issued the Admission ID.​

 

 

 

Only a single Item shall be included in this Sequence.​

>Include Table 10-17 “HL7v2 Hierarchic Designator Macro​

 

Attributes”​

 

 

 

Admitting Diagnoses Description​

 

(0008,1080)​

Description of admitting diagnosis (diagnoses) for the patient.​

AdmittingDiagnosesCodeSequence​

(0008,1084)​

Coded admitting diagnosis (diagnoses) for the patient.​

 

 

 

One or more Items shall be included in this Sequence.​

>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

Reason for Visit​

 

(0032,1066)​

Reason(s) for this visit by the patient to the facility or provider.​

Reason for Visit Code Sequence​

 

(0032,1067)​

Coded reason(s) for this visit by the patient to the facility or​

 

 

 

provider.​

 

 

 

Note​

 

 

 

If an HL7 message is available with a PV2 segment​

 

 

 

correspondingtothisvisit,potentialcodesmaybefound​

 

 

 

in Admit Reason PV2-3.​

 

 

 

One or more Items are permitted in this Sequence.​

>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

Referenced Request Sequence​

 

(0040,A370)​

Requested Procedures to which the Procedure Step contributes.​

 

 

 

Zero or more Items shall be included in the Sequence.​

>Study Instance UID​

 

(0020,000D)​

Unique identifier for the Study.​

>Accession Number​

 

(0008,0050)​

An identifier of the order for the Study.​

>Issuer of Accession Number​

 

(0008,0051)​

Identifier of the Assigning Authority that issued the Accession​

Sequence​

 

 

Number.​

 

 

 

Only a single Item shall be included in this Sequence.​

>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro​

 

Attributes”​

 

 

 

>Requested Procedure Code​

 

(0032,1064)​

Procedure Type of the Requested Procedure.​

Sequence​

 

 

Zero or one Item shall be included in this Sequence.​

 

 

 

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

>Placer Order Number / Imaging​

 

(0040,2016)​

The order number assigned to the Service Request by the party​

Service Request​

 

 

placing the order.​

>Order Placer Identifier Sequence​

 

(0040,0026)​

Identifier of the Assigning Authority that issued the Placer Order​

 

 

 

Number.​

Only a single Item shall be included in this Sequence.​

- Standard -​

 

DICOM PS3.3 2020a - Information Object Definitions​

Page 1535​

Attribute Name​

Tag​

Attribute Description​

 

>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro​ Attributes”​

>Filler Order Number / Imaging​

(0040,2017)​

Service Request​

 

>Order Filler Identifier Sequence​

(0040,0027)​

The order number assigned to the Service Request by the party​ filling the order.​

Identifier of the Assigning Authority that issued the Filler Order​ Number.​

Only a single Item shall be included in this Sequence.​

>>Include Table 10-17 “HL7v2 Hierarchic Designator Macro​ Attributes”​

>Requested Procedure ID​

(0040,1001)​

Identifier of the related Requested Procedure.​

>Requested Procedure Description​

(0032,1060)​

Institution-generateddescriptionorclassificationoftheRequested​

 

 

Procedure.​

>Reason for the Requested​

(0040,1002)​

Reason for requesting this procedure.​

Procedure​

 

 

> Reason for Requested Procedure​

(0040,100A)​

Coded reason for requesting this procedure.​

Code Sequence​

 

Zero or more Items shall be included in the Sequence.​

 

 

>>Include Table 8.8-1 “Code Sequence Macro Attributes”​

No Baseline CID is defined.​

>Requested Procedure Comments​

(0040,1400)​

User-defined comments on the Requested Procedure.​

>Confidentiality Code​

(0040,1008)​

Confidentiality Constraints on the Requested Procedure by the​

 

 

party filling the order.​

>Names of Intended Recipients of​

(0040,1010)​

Names of the physicians, who are intended recipients of results.​

Results​

 

 

>ImagingServiceRequestComments​

(0040,2400)​

User-defined comments on the Service Request.​

>Requesting Physician​

(0032,1032)​

Physician who requested the Service Request.​

>Requesting Service​

(0032,1033)​

Institutionaldepartment,unitorservicewheretherequestinitiated.​

>RequestingServiceCodeSequence​

(0032,1034)​

Institutionaldepartment,unitorservicewheretherequestinitiated.​

 

 

Equivalent to HL7 v2.x ORC-17.​

 

 

See Note 1.​

 

 

Only a single Item shall be included in this Sequence.​

>Issue Date of Imaging Service​

(0040,2004)​

Date on which the Service Request was issued by the requester.​

Request​

 

 

>Issue Time of Imaging Service​

(0040,2005)​

Time at which the Service Request was issued by the requester.​

Request​

 

 

>Referring Physician's Name​

(0008,0090)​

The physician who referred the Patient to the physician or service​

 

 

issuing the Service Request.​

 

 

Note​

 

 

This is generally the recipient of any report generated​

 

 

by the Service Request.​

Replaced Procedure Step Sequence​

(0074,1224)​

Canceled procedure step(s) that are replaced by this procedure​

 

 

step.​

Zero or more Items shall be included in the Sequence.​

>Include Table 10-11 “SOP Instance Reference Macro Attributes”​

- Standard -​